ACTROS.c

The Functional, Customized Designed Control System for Traffic Signals

ACTROS.c The Functional, Customized Designed Control System for Traffic Signals

The various supported central interfaces make for easy integration into all important traffic management environments. For this purpose, especially the open standard for central interfaces, OCIT, is fully supported. ACTROS also supports manufacturer-specific interfaces, including SIEMENS computer interfaces. ACTROS performs the following control processes: LISA+, VS-PLUS, PDM/TL (with motion), TRELAN/TRENDS, as well as additional modifications within individual programme sequences. The extensively equipped standard traffic engineering platform LISA+ is primarily used.
 

Technical Details

Housing
Standard cabinet with / without public utility part Size 0 as per DIN 43629 Part 1, IP54
Control Electronics
Max. number of signal groups 18
Max. number of lamp outputs 72
Number of lamp  outputs per control board 24
Max. number of I/Os 48
Number of I/Os per I/O card 16 inputs, 8 outputs
Traffic-related control

Fixed time programme, clock control, signal group and phase-oriented, traffic dependent control, coordinated activation point control LISA+, or freely programmable in Java control elements such as VS-Plus , PDMe/TL, MOTIONe, Trelan Trends , BALANCE

Central operation / interface

OCIT, V1.1 and V2.0 as well as Profile 2 and Profile 3, SB12, SB15, SB16, VnetS, SSI, DVI 35, CANTO, ACTROS.connect

Operation Control unit, integrable manual control unit, web server
System clock 0.5 s, 1 s
Signal sequence

Freely programmable, standard as per guidelines for traffic signal systems (RiLSA)

Public transport R09 messages according to the VÖV 04.05.1 standard
Signal safeguarding

Designed with fail-safe technology; current and voltage monitoring of all lamp outputs as per DIN VDE 0832 Part 100 and the guidelines for traffic signal systems (RiLSA).

Power Electronics
Max. power consumption without lamp wattage Typ. 50 VA, max. 300 W
Mains voltage 230 V (-15 … +10 %)
Power frequency 50 Hz (-5 … +5 %)
Permissible lamp voltages 40 V (OCIT-LED compliant) / 230 V
Lamp wattage per  signal output

8 to 460 W in the case of 230 V signal transmitters, 3 to 52 W in the case of 40 VLED signal transmitters

Max. lamp wattage per signal output 460 W or 2 A
Max. lamp wattage per control unit 3,000 W or 13 A
Max. lamp wattage per control card 1,800 W or 8 A