LIMBOPLAST KSP 120 UNIVERSAL belongs to the group of solvent-free, multi-component, reactive systems and consists of two or more components which chemically react with each other. It can be applied as type I marking as well as type II rain safety marking and has been testet on the wear simulator at the German Road Institute (BASt).


RPA-Test Reports by BAST for
LIMBOPLAST KSP 120 UNIVERSAL

Test report-no.

Layer
thickness

Consumption

Drop-on material (DOM)

Traffic technological
properties




mm


material

DOM

Identification
(divergent identification possible - see relevant test reprot)

New condition

Used condition

kg/m²

kg/m²

Type I markings

2011 1DY 01.14

0.3


0.474


0.35


Swarcoflex 100-800 T18 M30

P7, S1, R5, Q5, T2

P7, S2, R5, Q5


2012 1DY 08.12

0.3

0.474

0.30

Swarcolux 50 212-1000 T18 M30

P6,S2,R5,Q5,T2

P6, S2, R5, Q5

2016 1DY 08.07

0.3

0.474

0.32

Swarcolux P21 T18 M25

P7, S1, R5, Q5, T2

P7, S1, R5, Q5

2019 1DY 02.06

0.3

0.474

0.32

Swarcolux P21 T18 M25

P7, S1, R5, Q5, T2

P7, S2, R5, Q5

2002 1DY 07.21

0.4

0.632

0.32

Swarcolux P21 T14 M25

P7, S2, R4, Q5, T3

P7, S1, R4, Q5

2012 1DY 08.13

0.4

0.632

0.40

Swarcolux 50 212-1000 T18 M30

P6, S2, R5, Q5, T2

P6, S1, R5, Q5

2015 1DY 05.18

0.4

0.632

0.40

Swarcolux 50 212-1000 T18 MK30

P7, S1, R5, Q5, T2

P7, S1, R5, Q5

2002 1DY 07.23

0.4

0.632

0.78

Reactive beads type I 3:1

P7, S2, R5, Q5, T2*

P7, S2, R5, Q5*

2016 1DY 08.08

0.4

0.632

0.40

Swarcolux P21 T18 M25

P7, S1, R5, Q5, T2

P7, S1, R5, Q5

2019 1DY 02.07

0.4

0.632

0.40

Swarcolux P21 T18 M25

P7, S1, R5, Q5, T2

P7, S2, R5, Q5

2019 1DY 02.08

0.4

0.632

0.40

Reactive Glass beads Type I 3:1

P7, S1, R4, Q5, T3

P7, S2, R4, Q5

2019 1DY 02.09

0.4

0.632

0.40

Swarco SOLIDPLUS 10 P21 T18 M25

P7, S1, R5, Q5, T2

P7, S2, R5, Q5

2002 1DY 07.22

0.5

0.790

0.40

Swarcolux P21

P7, S2, R5, Q5, T3

P7, S1, R4, Q5

2006 1DY 06.11

0.6

0.948

0.70

Swarcolux P21

P7, S1, R4, Q5, T2

P7, S1, R3, Q5

2019 1DY 02.12

0.6

0.948

0.60

Swarco SOLIDPLUS 10 P21 T18 M25

P7, S1, R5, Q5, T2

P7, S2, R5, Q5

Type II markings

2002 1DY 06.18

0.6

0.948

0.60

Megalux 600-1500 T14 K25

P7, S2, R5, RW6, Q5, T3

P7,S1,R5,RW6,Q5

2005 1DY 09.08

0.6

0.948

0.45

Megalux 600-1500 T14 K25

P7, S3, R5, RW6, Q5, T2

P7, S1, R5, RW5, Q5

2011 1DY 01.12

0.6

0.948

0.47

Swarcolux 50 212-1400 T18 MK 30

P7, S3, R5, RW6, Q5, T2

P7, S1, R5, RW5, Q5

2015 1DY 05.15

0.6

0.948

1.20

Reactive beads type II 3:1

P7, S1, R5, RW5, Q4, T2

P7, S1, R5, RW4, Q4

2016 1DY 08.09

0.6

0.948

0.50

Swarcolux 50 S+10 425 - 1.400 T18 MK30

P7, S1, R5, RW6, Q5, T2

P7, S1, R5, RW5, Q5

2018 1DY 01.10

0.6

0.948

0.50

Swarcolux 50 425 - 1400 T18 MK30

P7,S1,R5,RW6,Q5,T2

P7, S1, R5, RW5, 5

2019 1DY 02.18

0,6

0,948

0,60

Swarco SOLIDPLUS 10 425 - 1.400 T18 MK30

P7, S1, R5, RW6, Q5, T2

P7, S1, R5, RW6, Q5

2011 1DY 01.13

0.7

1.106

0.47

Swarcolux 50 212-1400 T18 MK 30

P7, S3, R5, RW6, Q5, T2

P7, S1, R5, RW5, Q5

2019 1DY 01.15

0,7

1,106

0,70

Swarco SOLIDPLUS 10 425 - 1.400 T18 MK30

P7, S1, R5, RW4, Q5, T2

P7, S1, R5, RW4, Q5 

2005 1DY 09.07

0.75

1.185

0.60

Megalux 600-1500 T14 K25

P7, S4, R4, RW5, Q5, T2

P7, S2, R4, RW4, Q5

Type II markings KSP 120 Universal Injection

2006 1DY 06.13

0.4 wet


>0.6 with injection

0.632


0.40



0.40

Megalux 600-1500 T14 K25 (Injection)

Swarcolux P21 after gritted

P7, S2, R5, RW4, Q5, T2

P7, S2, R4, RW2, Q5

2015 1DY 05.17

0.4

0.632

0.35



0.40

Megalux 600-1400 T18 M25 (Injection)

Swarcolux P21 T18 M25 after gritted

P7, S1, R4, RW5, Q5, T2

P7, S1, R5, RW3, Q5

2005 1DY 09.09


0.6 wet


1.6 with injection

0.948

0.40



0.40

Megalux 600-1500 T14 K25 (Injection)

Swarcolux P21 after gritted

P7, S2, R4, RW3, Q5, T2

P7, S1, R4, RW2, Q5

Type II markings KSP 120 Universal double layer (0.5 + 0.7 mm; 0.6 + 0.6 mm; 0.6 + 0.5 mm)

2002 1DY 06.21

1) 0.6


2) 0.6

0.948


0.948

0.40


0.60

Megalux 600-1500 T14 K25

Megalux 600-1500 T14 K25

P7, S2, R5, RW5, Q5, T3

P7, S1, R5, RW4, Q5

2002 1DY 06.22

1) 0.5


2) 0.7

0.790


1.106

0.40


0.60

Megalux 600-1500 T14 K25

Megalux 600-1500 T14 K25

P7,S2,R5,RW5,Q5,T3

P7,S2,R5,RW4,Q5

2004 1DY 06.05

1) 0.6


2) 0.5

0.948


0.790

0.40


0.60

Megalux 600-1500 T14 K25

Megalux 600-1500 T14 K25

P7,S3,R4,RW5,Q5,T2

P7,S1,R4,RW4,Q5

2012 1DY 08.09

1) 0.6


2) 0.6

0.948


0.948

0.60


0.60

Swarcolux 50 212-1400 T18 MK 30

Swarcolux 50 212-1400 T18 MK 30

P7, S4, R5, RW3, Q5, T2

P7, S2, R5, RW4, Q5

*divergent details to test-report – classification based on traffic technological properties according to ZTV M 13  

Downloads