The functional, customized designed control system for traffic signals

Choose ACTROS.c and you receive a functional control system for traffic signals.

The various supported central interfaces make for easy integration into all important traffic management environments. For this purpose, especially the open standard for central interfaces, OCIT, is fully supported. ACTROS also supports manufacturer-specific interfaces, including SIEMENS computer interfaces. ACTROS performs the following control processes: LISA+, VS-PLUS, PDM/TL (with motion), TRELAN/TRENDS, as well as additional modifications within individual program sequences. The extensively equipped standard traffic engineering platform LISA+ is primarily used.


Standard cabinet with / without public utility part

Size 0 as per DIN 43629 Part 1, IP54


Max. number of signal groups


Max. number of lamp outputs


Number of lamp outputs per control board


Max. number of I/Os


Number of I/Os per I/O card

16 inputs, 8 outputs

Traffic-related control

Fixed time program, clock control, signal group and phase-oriented, traffic dependent control, coordinated activation point control LISA+, or freely programmable in Java control elements such as VS-Plus , PDMe/TL, MOTIONe, Trelan Trends ,BALANCE

Central operation / interface

OCIT, V1.1 and V2.0 as well as Profile 2 und Profile 3, SB12, SB15, SB16, VnetS,

SSI, DVI 35, CANTO, ACTROS.connect


Control unit, integrable manual control unit, web server

System clock

0.5 s, 1 s

Signal sequence

Freely programmable, standard as per guidelines for traffic signal systems (RiLSA)

Public transport

R09 messages according to the VÖV 04.05.1 standard

Signal safeguarding

Designed with fail-safe technology; current and voltage monitoring of all lamp

outputs as per DIN VDE 0832 Part 100 and the guidelines for traffic signal systems



Max. power consumption without lamp wattage

Typ. 50 VA, max. 300 W

Mains voltage

230 V (-15 … +10 %)

Power frequency

50 Hz (-5 … +5 %)

Permissible lamp voltages

40 V (OCIT-LED compliant) / 230 V

Lamp wattage per signal output

8 to 460 W in the case of 230 V signal transmitters, 3 to 52 W in the case of 40 V

LED signal transmitters

Max. lamp wattage per signal output

460 W or 2 A

Max. lamp wattage per control unit

3,000 W or 13 A

Max. lamp wattage per control card

1,800 W or 8 A