Individual Parking Space Monitoring - Sensors
Individual Parking Space Monitoring – The Optimum Solution
Efficient marketing of parking spaces is decisive for the economic success of a car park operator. Constantly increasing cost pressure requires optimum utilization of available parking spaces.
INDIVIDUAL PARKING SPACE MONITORING
The ultrasonic sensor determines the distance to the ground. If the distance is reduced due to a vehicle parking under the sensor, the „Occupied“ status is sent to the higher-level area controller. The Central Station displays the change in status, and the area controller activates the optionally available parking indicator light accordingly.
Up to 75 sensors can be connected to each area controller bus. Individual addresses can be set on the sensor by means of DIP switches. The sensors have an integrated red and green LED. Additionally, in case architectural circumstances (columns, etc.) block visibility, a separate bay light can be connected to the sensor.
THE SYSTEM IS BUILT ON FOUR COMPONENTS:
1. Ultra sonic sensors
2. Area controller
3. Parking space indicator (optional)
4. Central controller (optional)
- Exact detection of all unoccupied parking spaces
- Precise directing of vehicles to the unoccupied spaces
- Reduction of traffic looking for unoccupied spaces
- Highly improved acceptance of the car park
- Efficient use of existing parking capacities
- Increase in utilisation / income
- Statistical evaluation of car park occupancy
- Car theft monitoring
| Measurement method: |
Ultrasonic distance measurement |
| Dimensions (W x H x D): |
79 x 40 x 20 mm |
| Interior range: |
0.3 to 3.0 m |
| Resolution: |
0.01 m |
| Operating frequency: |
41 kHz |
| Band width: |
< 1kHz |
| Standard: |
integrated red / green indicator LEDs |
| Option: |
separate bay indicator light |
| Power supply: |
12 V DC |
| Data transfer: |
RS485 2-wire to SWARCO Area Controller |
| Operating temperature: |
-10°C to +40°C |
| Addressability: |
1 – 128 |
MOUNTING:
The sensors are simply clipped into the cable ducts, no tools required. Sensor interconnection, as well as sensor bus connection to the area controllers are realized using pre-manufactured 10-wire ribbon cables. LL54608.CSA.AWm I A/b 105c. 300v.FT1.